> Meet a variety of contact liquid level measurement need
> The distance can be adjusted according to the detected object
(sensitivity button)
> PTEE shell, with excellent chemical resistance and oil resistance
>Acid and alkali corrosion resistance
> Resistant to strong magnetic interference
> Multi-turn potentionmeter adjustment
| NPN NO | CR18XTCF05DNO | CR18XTCN08DNO |
| NPN NC | CR18XTCF05DNC | CR18XTCN08DNC |
| NPN NO+NC | CR18XTCF05DNR | CR18XTCN08DNR |
| PNP NO | CR18XTCF05DPO | CR18XTCN08DPO |
| PNP NC | CR18XTCF05DPC | CR18XTCN08DPC |
| PNP NO+NC | CR18XTCF05DPR | CR18XTCN08DPR |
| Installation type | Flush | No-flush |
| Specifications | ||
| Rated distance | 5mm | 8mm |
| Adjust the distance | 2…7.5mm(adjustable) | 3…12mm(adjustable) |
| Adjustment method | Multi-turn potentiometer adjustment | |
| Shape specification | M18* 70.8 mm | |
| Output type | NPN/PNP NO/NC/NO+NC | |
| Supply voltage | 10…30 VDC | |
| Standard target | Fe 18*18*1t(Ground) | Fe 24*24*1t(Ground) |
| Switch point offset [%/Sr] | ≤±10% | |
| Hysteresis range [%/Sr] | 3…20% | |
| Repetitive error | ≤5% | |
| Load current | ≤200mA | |
| Residual voltage | ≤2.5V | |
| Consumption current | ≤15mA | |
| Circuit protection | Short circuit protection, overload protection,reverse polarity protection | |
| Output indication | Yellow LED | |
| Ambient temperature | -25℃...70℃ | |
| Environment humidity | 35...95%RH | |
| High pressure resistant | 1000VAC 50/60Hz 60s | |
| Switching frequency | 20Hz | |
| Vibration resistant | 10…55Hz, Dual amplitude 1mm 2 hours each in X, Y, and Z directions | |
| Impulse withsand | 30g/11ms 3 times each for X,Y,Z direction | |
| Protection degree | IP67 | |
| Housing material | PTFE White | |
| Connection | 2M PUR cable | |