Enhanced and long distance measurement sensor in principle of TOF. Reliably developped with unique technology to promise the capability and high performance price ratio, the most economical solutions for different applicaitons and industrial demands. Connection ways in 2m 5pins PVC cable available for RS-485, while 2m long 4pins PVC cable for 4...20mA. Enclosed housing, water proof for harsh environments to meet IP67 protection level.
> Distance measurement detection
> Sensing distance: 0.1...8m
> Resolution: 1mm
> Light source: Infrared laser(850nm); Laser level: Class 3
> Housing size: 51mm*65mm*23mm
> Output: RS485 (RS-485(Support Modbus protocol)/4...20mA/PUSH-PULL/NPN/PNP And NO/NC Settable
> Distance setting: RS-485:button/RS-485 setting; 4...20mA:button setting
> Operating temperature:-10…+50℃;
> Connection: RS-485:2m 5pins PVC cable;4...20mA:2m 4pins PVC cable
> Housing material: Housing: ABS; Lens cover: PMMA
> Complete circuit protection: Short circuit, reverse polarity
> Protection degree: IP67
> Anti-ambient light: <20,000lux
Plastic Housing | ||||
RS485 | PDB-CM8DGR | |||
4..20mA | PDB-CM8TGI | |||
Technical specifications | ||||
Detection type | Distance measurement | |||
Detection range | 0.1...8m Detection object is 90% white card | |||
Supply voltage | RS-485:10...30VD;4...20mA:12...30VDC | |||
Consumption current | ≤70mA | |||
Load current | 200mA | |||
Voltage drop | <2.5V | |||
Light source | Infrared laser(850nm); Laser level: Class 3 | |||
Working principle | TOF | |||
Average optical power | 20mW | |||
Impulse duration | 200us | |||
Impulse frequency | 4KHZ | |||
Testing frequency | 100HZ | |||
Light spot | RS-485:90*90mm(at 5m meter); 4...20mA:90*90mm(at 5m meter) | |||
Resolution | 1mm | |||
Linear accuracy | RS-485:±1%F.S.; 4...20mA:±1%F.S. | |||
Repeat accuracy | ±1% | |||
Response time | 35ms | |||
Dimensions | 20mm*32,5mm*10.6mm | |||
Output 1 | RS-485(Support Modbus protocol); 4...20mA(Load resistance<390Ω) | |||
Output 2 | PUSH-PULL/NPN/PNP And NO/NC Settable | |||
Dimensions | 65mm*51mm*23mm | |||
Distance setting | RS-485:button/RS-485 setting; 4...20mA:button setting | |||
Indicator | Power indicator: Green LED; Action indicator: Orange LED | |||
Hysteresis | 1% | |||
Circuit protection | Short circuit protection, overload protection, reverse polarity protection,Zener protection | |||
Built-in function | Button to lock, button to unlock, action point setting,Output setting, average setting,Single point teach; Window teach mode setting,Output curve up/ down; factory date reset | |||
Service environment | Operating temperature:-10…+50℃; | |||
Anti-ambient light | <20,000lux | |||
Degree of protection | IP67 | |||
Housing material | Housing: ABS; Lens cover: PMMA | |||
Vibration resistance | 10...55Hz Double amplitude1mm,2H each in X,Y,Z directions | |||
Impulse resistance | 500m/s²(About 50G) 3 times each in X,Y,Z directions | |||
Connection way | RS-485:2m 5pins PVC cable;4...20mA:2m 4pins PVC cable | |||
Accessory | Screw(M4×35mm)×2, Nut×2, Washer×2,Mounting bracket, Operation manual |